Skip to main content
Brand Name: BAXI
Model Name: MONO 2 AWHP 16TR
Model Structure (mono/split): Monobloc
Type: Air to water
Rated heat output, Prated[kW] 13.02
Low temperature heat pump No
Seasonal Space Heating Efficiency, ηs [%] 133.00
Water heating efficiency, ηwh [%] N/A
General Details
Product index number 971217
Source of data Ecodesign declaration and independently certified data
First year of manufacture 2023
Final year of manufacture Current
Identification
Manufacturer's name BDR Thermea France
Brand Name BAXI
Model Name MONO 2 AWHP 16TR
Model Qualifier HP40-13-3PHMB
Model Structure Monobloc
Appliance ID
Basic Properties
Heat Pump Type Air to water
Low Temperature Heat Pump No
Fuel Type Electricity
Indoor unit power supply N/A
Outdoor unit power supply 3-phase
Equipped with supplementary heater Yes
Heat pump combination heater No
Rated Air Flow [m3/h] 4650
Space Heating EN Test Standard EN 14825
Space Heating Efficiency Class (medium temperature application) A++
Space Heating Efficiency Class (low temperature application) A+++
Seasonal space heating efficiency, ηs [%] (medium temperature application) 133
Seasonal space heating efficiency, ηs [%] (low temperature application) 182
Water Heating EN Test Standard N/A
Water Heating Efficiency Class N/A
Water Heating Efficiency, ηwh [%] N/A
Temperature Control (Capacity Control) Variable
Operation Limit Temperature, TOL [°C] -10
Heating Water Operation Limit Temperature WTOL [°C] 65
Heat Pump Test Data I.S. EN 14825
Low Temperature Application Condition, 35°C
Low Temperature Test Condition Yes
Degradation co-efficient 0.9
Test Condition - Low (35°C)
Tj A
(88%)
-7 °C
B
(54%)
2 °C
C
(35%)
7 °C
D
(15%)
12 °C
E
(100%)
TOL
Declared Heating Capacity (kW) 13.45 8.56 5.7 3.78 12.52
Coefficient of Performance (kW/kW) 2.72 4.41 6.56 8.51 2.48
Primary Energy Ratio (%) N/A N/A N/A N/A N/A
Intermediate Temperature Application Condition, 45°C
Intermediate Temperature Test Condition No
Medium Temperature Application Condition, 55°C
Medium Temperature Test Condition Yes
Degradation co-efficient 0.9
Test Condition - Medium (55°C)
Tj A
(88%)
-7 °C
B
(54%)
2 °C
C
(35%)
7 °C
D
(15%)
12 °C
E
(100%)
TOL
Declared Heating Capacity (kW) 11.5 7.2 4.7 3.3 N/A
Coefficient of Performance (kW/kW) 1.99 3.34 4.61 6.07 1.8
Primary Energy Ratio (%) N/A N/A N/A N/A N/A
High Temperature Application Condition, 65°C
High Temperature Test Condition No
F-Gas Details
F-Gas Name R32
F-Gas Quantity 1.75
F-Gas GWP 675
Record last updated
Details available from:

Baxi Heating UK
Brooks House
Warwick
Warwickshire
United Kingdom
0844 871 1525

Www.baxi.co.uk

Return to HARP search