Skip to main content
Brand Name: Stiebel Eltron
Model Name: WPL-A 07 HK 230 Premium
Model Structure (mono/split): Monobloc
Type: Air to water
Rated heat output, Prated[kW] 7.96
Low temperature heat pump No
Seasonal Space Heating Efficiency, ηs [%] 152.90
Water heating efficiency, ηwh [%] N/A
General Details
Product index number 971311
Source of data Ecodesign declaration and independently certified data
First year of manufacture 2021
Final year of manufacture Current
Identification
Manufacturer's name STIEBEL ELTRON GmbH & Co. KG (DE)
Brand Name Stiebel Eltron
Model Name WPL-A 07 HK 230 Premium
Model Qualifier
Model Structure Monobloc
Appliance ID 200123
Basic Properties
Heat Pump Type Air to water
Low Temperature Heat Pump No
Fuel Type Electricity
Indoor unit power supply N/A
Outdoor unit power supply Single phase
Equipped with supplementary heater Yes
Heat pump combination heater No
Rated Air Flow [m3/h] 2250
Space Heating EN Test Standard EN 14825
Space Heating Efficiency Class (medium temperature application) A+++
Space Heating Efficiency Class (low temperature application) A+++
Seasonal space heating efficiency, ηs [%] (medium temperature application) 152.9
Seasonal space heating efficiency, ηs [%] (low temperature application) 192.3
Water Heating EN Test Standard N/A
Water Heating Efficiency Class N/A
Water Heating Efficiency, ηwh [%] N/A
Temperature Control (Capacity Control) Variable
Operation Limit Temperature, TOL [°C] -10
Heating Water Operation Limit Temperature WTOL [°C] 75
Heat Pump Test Data I.S. EN 14825
Low Temperature Application Condition, 35°C
Low Temperature Test Condition Yes
Degradation co-efficient 0.9
Test Condition - Low (35°C)
Tj A
(88%)
-7 °C
B
(54%)
2 °C
C
(35%)
7 °C
D
(15%)
12 °C
E
(100%)
TOL
Declared Heating Capacity (kW) 7.13 4.34 3.19 3.75 6.86
Coefficient of Performance (kW/kW) 3 4.82 6.66 8.4 2.8
Primary Energy Ratio (%) N/A N/A N/A N/A N/A
Intermediate Temperature Application Condition, 45°C
Intermediate Temperature Test Condition No
Medium Temperature Application Condition, 55°C
Medium Temperature Test Condition Yes
Degradation co-efficient 0.9
Test Condition - Medium (55°C)
Tj A
(88%)
-7 °C
B
(54%)
2 °C
C
(35%)
7 °C
D
(15%)
12 °C
E
(100%)
TOL
Declared Heating Capacity (kW) 7 4.3 3 3.6 N/A
Coefficient of Performance (kW/kW) 2.43 3.79 5.22 6.33 2.14
Primary Energy Ratio (%) N/A N/A N/A N/A N/A
High Temperature Application Condition, 65°C
High Temperature Test Condition No
F-Gas Details
F-Gas Name R454C
F-Gas Quantity 3
F-Gas GWP 148
Record last updated
Details available from:

STIEBEL ELTRON GmbH & Co. KG Ltd
33
Doktor-Stiebel Str
Holzminden
Germany

Www.stiebel-eltron.com

Return to HARP search